Understanding Approved Document B: fire safety guidance for commercial buildings

Project leads

Contributors

Ian Abley

Ian joined TFT in December 2025. He previously worked for RISC Authority, the insurance sector’s research department at the Fire Protection Association, where he published The A to Z of Essential Principles for the Protection of Buildings.

Deregistered as an architect, Ian has focused on specification, testing, and site-based inspections of materials and workmanship to ensure compliance with contracts, leading through to handover and occupation.

He has researched the issue of Class 0, highlighted by the Grenfell Tower fire, as well as industry reforms relating to Modern Methods of Construction.

‍

Robin Holme

Robin is Director in charge of the Leeds office, bringing experience in project management and monitoring, contract administration, technical due diligence, building pathology and party wall surveying. He also has a keen interest in developing sustainability opportunities across his projects and services.

He has recent experience acting as programme director for high rise cladding remediation works for a leading national student accommodation provider and having completed the RICS EWS1 Assessor course, has enhanced understanding and competence in cladding consultancy. He has led and developed building and project consultancy teams nationally while working in the Leeds marketplace for over 20 years.

Robin’s experience includes new build, refurbishment and fit-out projects as well as managing survey programmes regionally and nationally. His work covers commercial property sectors including industrial, retail, residential, education and healthcare, for clients such as British Land, Patrizia, Land Securities, Quadrant Estates, Walgreens-Boots Alliance, CO-OP, Aberdeen and the Department for Transport.

Approved Document B is one of the main sources of guidance for meeting the fire safety requirements of the Building Regulations in England.

For commercial property owners, developers and project teams, understanding the document means more than knowing the basic requirements. The guidance has been amended several times in recent years, further changes are approaching, and applying it to refurbishment or existing buildings can require careful interpretation.

This guide explains what the guidance covers, which parts are most relevant to commercial property and some of the issues to consider when applying it in practice, as part of our wider series on delivering safer buildings.

What is Approved Document B?

Approved Document B provides statutory guidance on ways to meet the fire safety requirements of the Building Regulations 2010 in England.

It is divided into two volumes:

• Volume 1: Dwellings

• Volume 2: Buildings other than dwellings

For commercial property owners and project teams, Volume 2 is the main reference point. It covers buildings such as offices, shops, hotels, industrial premises and many other types of non-residential property.

Approved Document B explains ways the requirements of the Building Regulations may be satisfied. The legal requirements themselves sit within the Building Regulations.

Following the guidance is one recognised route towards compliance, but it isn’t the only possible approach. Other solutions may be appropriate where they can be shown to meet the underlying regulatory requirements.

What does the guidance cover?

For buildings other than dwellings, Volume 2 addresses five main areas of fire safety:

• B1: Means of warning and escape, including fire detection, alarm systems and escape routes

• B2: Internal fire spread through linings, including the fire performance of wall and ceiling surfaces

• B3: Internal fire spread through the structure, including fire resistance, compartmentation and measures intended to restrict fire and smoke spread

• B4: External fire spread, including external walls, roofs and the risk of fire spreading between buildings

• B5: Access and facilities for the fire service, including access to buildings and facilities that support firefighting operations

The document also includes guidance relating to the materials and workmanship requirements in Regulation 7 and the provision of fire safety information under Regulation 38.

For commercial projects, these areas often need to be considered together. Decisions about layout, structure, materials or the façade can affect several parts of the fire strategy.

Has the guidance changed?

The guidance has undergone a series of amendments in 2025 and 2026, with more changes to come in 2029.

For owners and project teams, the dates are important because transitional provisions can determine which version applies to a particular project.

2 March 2025

Changes introduced in March 2025 included:

• removal of references to the BS 476 national classification system for reaction to fire and roofs

• new sprinkler provisions for care homes

• a consequential amendment relating to Regulation 38 and fire safety information

The European classification system now provides the route used by the guidance for reaction-to-fire and roof classifications. See the government summary of the amendments.

30 September 2026

Further amendments take effect on 30 September 2026.

These primarily concern residential buildings, including the provision of more than one common stair in blocks of flats with a storey 18m or more above ground level, alongside provisions supporting evacuation lifts.

For many conventional commercial properties, these changes will have limited direct impact. They may still be relevant to mixed-use developments or projects containing residential elements, so project teams should make sure they’re working from the appropriate version of the guidance.

2 September 2029

From 2 September 2029, references to the BS 476 national classification system for fire resistance are due to be removed.

The relevant European standards will then become the sole specification route within the guidance for fire-resistance classifications.

The dates are only part of the picture, as transitional arrangements can determine which version applies to a particular project.

How does the guidance apply to existing commercial buildings?

The Building Regulations are often associated with new construction, but they can also apply when work is carried out to an existing building.

This can include projects involving:

• Extensions

• Material alterations

• Certain changes of use

• Other building work that brings relevant requirements of the Building Regulations into play

Work to an existing building doesn’t automatically mean bringing the whole asset up to current new-build standards.

The work itself must meet the applicable requirements and, where the existing building doesn’t already comply with a relevant requirement, the work mustn’t leave it in a worse position than before.

The correct approach depends on the nature and extent of the work, the existing building and the requirements that are triggered.

A 2026 Building Safety Regulator consultation proposed consolidating and clarifying the guidance for building work to existing buildings. Those proposals aren’t yet current requirements, with implementation currently targeted for September 2029.

Does following the guidance guarantee compliance?

Following Approved Document B is an established way to demonstrate compliance with the Building Regulations, but it still needs to be applied in the context of the building and the project.

Approved Documents provide practical guidance that will be appropriate in many common situations. They don’t prescribe a solution for every possible design or set of circumstances.

A project may follow the recommendations closely, or it may use an alternative fire-engineered solution where the project team can demonstrate that the underlying functional requirements of the Building Regulations have been met.

This becomes particularly important for larger, more complex or unusual commercial buildings where the standard guidance may not fit the proposed design.

What if your building doesn’t fit the standard guidance?

In some projects, a compliant fire safety strategy may need to go beyond the standard solutions set out in the guidance.

This could arise because of:

• The size or complexity of the building

• Unusual layouts or uses

• Large numbers of occupants

• Mixed-use arrangements

• Constraints within an existing building

• Proposed materials or construction methods

• A design that departs from one of the recognised solutions

In these situations, specialist fire engineering input may be required to demonstrate how the design satisfies the relevant Building Regulations.

Bringing in specialist fire engineering advice early can help project teams test the proposed approach before it starts to affect design, procurement or programme.

What fire safety information needs to be handed over?

The guidance also deals with the information that needs to pass from the project team to those responsible for managing fire safety once building work is complete.

Under Regulation 38, where building work involves the erection, extension or change of use of a relevant building, fire safety information should be provided to the relevant dutyholder where the Regulatory Reform (Fire Safety) Order 2005 or the Building Safety Act 2022 applies, or will apply, to the building.

It’s also worth noting that material alterations don’t, by themselves, fall within the scope of Regulation 38.

For commercial owners and occupiers, good-quality information can make a significant difference later. Fire strategies, specifications, drawings and records of what was actually installed can support ongoing fire risk management, future alterations and technical due diligence.

Incomplete records can make those tasks considerably harder, particularly when an owner later needs to establish how an existing building was constructed.

How does this relate to a Fire Risk Assessment?

Approved Document B and a Fire Risk Assessment serve different purposes.

The guidance primarily supports compliance with the Building Regulations when designing and carrying out building work.

A Fire Risk Assessment, or FRA, considers the fire risks associated with a building in use and the measures needed to manage them. It forms part of the ongoing responsibilities of those with fire safety duties under the Regulatory Reform (Fire Safety) Order 2005.

That distinction is particularly important for existing buildings. A property may have been designed in accordance with the standards that applied when it was built, while its current use, condition or fire safety management raises different questions.

Where do FRAEW and PAS 9980 fit in?

External walls are one area where different parts of the fire safety framework can intersect.

Approved Document B includes guidance intended to restrict fire spread over and between external walls as part of Building Regulations compliance.

For certain existing buildings, separate assessment may later be required to understand the fire risk presented by the external wall as it has actually been constructed and is being used.

A Fire Risk Appraisal of External Walls (FRAEW) is a specialist appraisal of external wall fire risk. PAS 9980 provides a methodology for carrying out FRAEWs for existing multi-storey, multi-occupied residential buildings.

If you’re dealing specifically with an existing external wall, see our guides to when you need a FRAEW and understanding PAS 9980 for more detailed guidance.

What should commercial building owners and project teams consider?

Before progressing significant building work, it is worth establishing:

• which version of the guidance applies

• whether transitional arrangements affect the project

• which Building Regulations requirements are triggered by the proposed works

• whether the standard guidance is appropriate for the building and its use

• whether specialist fire engineering input is required

• how fire safety decisions interact with the façade, structure, building services and wider design

• what information needs to be recorded and handed over when work is completed

This is particularly relevant when working with an existing commercial building, where historic alterations, incomplete records and constraints within the existing fabric can make the position less clear.

In safe hands with TFT

TFT helps commercial building owners, investors and project teams understand fire safety requirements and bring the right technical expertise together at the right stage of a project.

Whether you’re planning works to an existing building, reviewing a potential acquisition or trying to understand the implications of changing guidance, we can help you establish the right approach and coordinate the next steps.

If you want to keep up to date with changes in legislation and regulation, technical challenges and new ways of working to achieve building safety, click here to join our In Safe Hands mailing list for monthly insights and advice from the team.

‍

Talk to our building safety specialists

TFT can help you review the available information, understand where further investigation may be needed and bring together the right technical expertise to decide the right next steps.

‍

Want to know more?

Get in touch

Related content

No items found.
No items found.